Sample Collection, Reception and Rejection SOP template (ISO 15189:2022)
Patient identification, sample labelling, transport, acceptance and rejection criteria. Supports ISO 15189:2022 7.2, 4.3.
Last reviewed
Purpose
A sample collection, reception and rejection procedure controls the steps that connect a patient and test request with a suitable specimen for examination. It guides collection staff, transport personnel and laboratory reception teams through identification, labelling, handling and acceptance decisions. Its scope should make clear which specimen types and collection settings are covered and where more specific instructions are needed.
A good version describes how patient identity is checked, how request information is linked to the sample and when labelling occurs. Collection requirements should address preparation, containers, volume and relevant timing. Transport and storage instructions need practical conditions and limits that reflect the examinations offered, together with arrangements for delays, leakage or missing information.
Acceptance and rejection criteria should be specific enough to support consistent decisions without encouraging unsafe disposal of difficult-to-replace material. Define who can authorise an exception, how clinical users are consulted and how any limitation is recorded and communicated. Include urgent and irreplaceable samples, traceable correction of identification issues and requests for recollection. Reception records should capture relevant discrepancies and actions so that recurring collection or transport problems can be discussed with the services involved.
Section outline
- Purpose
- Scope
- Patient identification and labelling
- Transport and storage
- Acceptance and rejection criteria
- Records
Headings only — the full template is drafted for your laboratory inside the app.
When to use it
- Standardising collection and reception across sites.
- Clarifying rejection criteria and exception authorisation.
- Addressing recurrent identification, transport or specimen-quality problems.
Tips for writing it well
- Use specimen-specific acceptance criteria rather than vague suitability statements.
- State who authorises exceptions for urgent or irreplaceable samples.
- Describe communication and recollection steps after rejection.
- Align transport limits with current examination-specific instructions.
Clauses it supports
Check the exact requirement in your licensed copy of the standard.